+27 73 502 9614 [email protected] Mon-Sat 8:00-17:30
A Complete Guide To Installing Your Car Charging Station

A Complete Guide To Installing Your Car Charging Station

Browse technical resources about solar mounting systems, tracker technology, structural design, and installation best practices.

  • Complete Guide to Fiber Optic Pigtail Interfaces

    Complete Guide to Fiber Optic Pigtail Interfaces

    This guide covers everything: what fiber optic pigtails are, how they differ from patch cords, which connector and polish type to specify, how to choose between mechanical and fusion splicing, and the real-world applications where pigtails are the right call. They are the bridge between fiber optic cables in the field and the equipment or patch panels that manage them. By combining factory-installed connectors with spliced bare fiber, pigtails ensure that network installers can create. A pigtail fiber indicates a short length of optical fiber cable that has a pigtail connector (for example, SC, FC, ST, LC, etc. ) fitted on one end and the other end undressed (for connection through fusion or splicing) to the main fiber optic cable. Compared with quick termination or epoxy and polish.

    [PDF Version]
  • Materials for installing tubular busbars

    Materials for installing tubular busbars

    Heat shrink tubing is used to insulate busbars by shrinking the tubing over the conductor using heat. This method provides a tight seal and protection against environmental factors. In this new edition the calculation of current-carrying capacity has been greatly simplified by the provision of exact formulae for some common busbar configurations and graphical methods for others. Insulating these components is crucial to prevent electrical faults, ensure safety, and maintain system integrity. The choice of insulation material affects the busbar's thermal performance, electrical. The purpose of this document is to detail the requirements of Northern Powergrid in relation to the tubular busbar systems and associated fittings detailed within this document. This document supersedes the following documents, all copies of which should be destroyed.

    [PDF Version]
  • Selection Guide for DFB Distributed Feedback Laser QSFP28 for Distribution Network Automation

    Selection Guide for DFB Distributed Feedback Laser QSFP28 for Distribution Network Automation

    This guide provides a systematic selection process to help you choose the right QSFP28 module every time. You will learn how to verify form factor compatibility, match fiber and distance requirements, validate switch compatibility, consider thermal constraints, and avoid. The acronym DFB laser stands for distributed feedback laser. Their key features relative to other semiconductor lasers are their single longitudinal mode (single frequency) emission profile, their high stability and their wavelength tunability. A DFB laser's periodic structure acts as a distributed reflector, providing optical feedback and. A distributed feedback (DFB) laser is a laser where the optical resonator is formed not by discrete mirrors at the ends (as in Fabry–Pérot laser diodes) but by a periodic variation of the refractive index or gain (a Bragg grating) distributed throughout the active medium.

    [PDF Version]
  • Column-mounted electrical distribution box size guide

    Column-mounted electrical distribution box size guide

    This report provides a comprehensive analysis of electrical distribution board (DB) box sizes, including physical dimensions, electrical capacities, and market trends based on current 2025-2026 standards. The box dimensions shown are inside dimensions. The EZ Box and EZ Trim are provided standard for Pow-R-Line 1X and Pow-R-Line 2X lighting panelboards, as well as Pow-R-Line 3X. This guide explains typical wall-mount and floor-standing dimensions, how to read catalog sizes, and how to choose the right enclosure size for your layout. In practice, “standard sizes” usually means the common size families. Clear detailed description of each size and easy to select with the ordering codes. Box with four studs and adjustable nuts for easy fit / easy remove of pan assembly. Easy fit of incomer devices, aluminum profile with plastic clip for self aligning feature of outgoing MCBs. Larger enclosures may be needed for outdoor use, better protection, or cooling components like fans or vents.

    [PDF Version]
  • Selection Guide for Low-Loss Active Optical Devices for Photovoltaic Power Plants

    Selection Guide for Low-Loss Active Optical Devices for Photovoltaic Power Plants

    Future PVLPCs must exhibit higher efficiencies and delivered power, robustness at rough environmental conditions, and lower manufacturing cost. This review aims at showing the routes to achieve these goals.


  • How to calculate bends when installing cable tray supports

    How to calculate bends when installing cable tray supports

    Calculate horizontal, vertical, or compound cable tray offsets based on bend angle, offset distance, and available installation space. This publication is intended as a practical guide for the proper and safe* installation of cable ladder systems, cable tray systems, channel support systems and associated supports. By contrast, a support element is constructed to support the previously described cable support lengths and fit-tings mechanically and to connect them to the structure, such as a. maintain spacing or to keep cables in place when the tray is ect the minimum bend ra-dius for cables as they exit the bottom of the cable tray. A rung spacing of 6 to 9 inches (150 to 230 mm) is preferable when the cable tray cont d for instrumentation and control applications that require. This guide covers the critical steps, from selecting the right electrical cable tray and performing accurate cable fill calculations to managing a safe cable pull through and ensuring all bonding and grounding requirements are met. The Ladder Tray features light, rugged, tubular steel construction.

    [PDF Version]
  • Base station optical cable usage

    Base station optical cable usage

    base station cable s serve as the backbone of fiber optic systems, linking various components to create an efficient network. Our base station and optical transport connectivity solutions address the demands of the always-on edge of expanding wireless infrastructure. Along with increased capacity demands driven by the explosion of cloud and connected device growth, engineers need interconnects that enhance the design. Fiber-optic cables offer several advantages over traditional copper cables, making them ideal for 5G signal transmission: High Bandwidth Capacity: Fiber-optic cables can support significantly higher bandwidths, enabling the transmission of large volumes of data at unprecedented speeds. Fiber links make system modifications and future upgrades simpler than would be possible with traditional copper links. To handle the high-frequency signals used in high-capacity communication, networks need to have high-performance transistors.

    [PDF Version]
  • Hazards of Communication Base Station Towers

    Hazards of Communication Base Station Towers

    Cell towers drop property values, create fire risks, and emit radiofrequency (RF) radiation. Children absorb higher rates of cell tower radiation and are biologically more vulnerable to the RF radiation emitted by cell towers, a fact that has long been acknowledged by medical. These towers have electronic equipment and antennas that receive and transmit cell phone signals using radiofrequency (RF) waves. Cell phone towers are still relatively new, and many people are understandably concerned about whether the RF waves they give off might possibly have health effects. At. Base stations transmit and receive radio waves to connect the users of mobile phones and other devices to mobile communications networks. The strength of the radio waves from base station antennas reduces rapidly with increasing distance and the levels at locations where the public can be exposed. We work to strengthen radiation protection of the public, patients and workers worldwide. Mobile telephony is now commonplace around the world.

    [PDF Version]
  • Secondary Pump Station Distribution Box

    Secondary Pump Station Distribution Box

    The Secondary Distribution Box (SDB) receives power from Main Power Distribution box via an extender cable and provides a central power distribution to feed normal branch circuits to the electric floor modules through snap-on extender cables. A feeder usually begins with a feeder breaker at the distribution substation. Many feeders leave substation in a concrete ducts and are routed to a nearby pole. At this. Volume 3 in this update is split into six sub-volumes, as following tables, for easy reference and timely update of individual sub-volume to address industry requirements and technological advancements. The following is a list of revisions in Vol. 3-04: Pump Station and Forcemain Design Guidelines. This allows multiple pumps to be driven simultaneously from a single power source. Thanks to the modular design, they can be perfectly tailored to any. This manual provides information and criteria pertinent to the design and layout of civil works flood control pumping stations.

    [PDF Version]
  • 30kW Photovoltaic Charging Module

    30kW Photovoltaic Charging Module

    Up to 825V DC input and output voltage range is from 150 to 1000VDC with 30kW output power. EMC/EMI satisfies TUV CE certification with class B level, and safety satisfies cTUVus and TUV CE certification. Also, this power converter supports the solar panel's DC power input with. UR100030-SW(EU) high power 30kW charging module is dedicated to application in the fast charging station. It has advantages such as high efficiency, low fan noise, high power density and high reliability. EMC/EMI satisfies TUV CE. 8 pcs 650 V Si Mos + 16 pcs Si diode 8 pcs 1200 V SiC Mos + 16 pcs Si diode 6 pcs SiC Mos + 12 pcs Si diode © STMicroelectronics - All rights reserved. The modular and scalable system is optimized for. The all new and innovative 30kW solar DC EV charger with DC input and MPPT functionality is a highly advanced and efficient solution for providing EV charging possibilities at sites with installed solar panels and no AC grid available. This solar panels fed EV charger, being an all-in-one-pack. Mekel's DC Charging Module is a high-performance power conversion unit that is crucial for the functioning of DC charging stations.

    [PDF Version]
  • Should charging pile cables be routed via conduit or cable tray

    Should charging pile cables be routed via conduit or cable tray

    The pathway is the plan, the trays and conduits are the buckets which contain the wires. Cable Trays: They are suitable for long, straight runs where a large number of wires are present. These rules shall be applied in the cabling engineering workflow for all subjects concerning or in relationship with cabling in the ITER facility. Both can meet code, but they behave very differently in cost, maintenance, scalability, and safety. Wet utilities are usually. Question 1: Can mechanical utility piping or tubing containing water or compressed air be installed in cable trays with electrical cables? Answer: No. Cable trays are a support system for electrical cables, power, signal, and communication and optical fiber cables. NEC section 300-8 does not permit. Charging pile installation and main matters - Bluesky is a provider of integrated energy refueling solutions for petrol, natural gas, hydrogen, and EV charging. Below, I will introduce to you what you should pay attention to when installing.

    [PDF Version]
  • Precautions for installing signal busbars

    Precautions for installing signal busbars

    This article deals with four significant precautions you should take – grouping conductors in parallel, short circuits, magnetic effects, operating current, and voltage drop. If you ask me, I will always prefer the prefabricated busbar trunking systems over cables, where possible, of course. There. Are you aware that improper installation of busbars can lead to costly and dangerous electrical failures? This article details the comprehensive standards for installing and inspecting busbars, including support brackets, insulators, and bus duct systems. However, many potential issues need to be addressed. Misalignment issues, overloading circuits, and improper connections are among the most common mistakes that can. Prepare the site by removing any dust or metal shavings. Method gives details of how the work will be carried out and how related.

    [PDF Version]

Need Product Pricing?

Contact us for competitive quotes on any of our fiber optic products

Get a Quote